Commands in DSR Application Subsystems
:MMEMory Subsystem
96
Agilent 81250 Parallel Bit Error Ratio Tester, Programming Reference, March 2006
:<Handle>:MMEMory:SETTing:NEW
Syntax
:<Handle>:MMEMory:SETTing:NEW
Description
Resets and creates an ‘untitled’ environment. Starting from default
values, a new setting can be created. To validate the new setting, it has
to be ‘saved’ or ‘saved-as’ a into the Agilent 81250 System’s database.
Return Value
None
Example
:_test:MMEM:SETT:NEW
:<Handle>:MMEMory:SETTing:DELete
Syntax
:<Handle>:MMEMory:SETTing:DELete <“SettingName”>
Parameters
<“SettingName”>
Setting to be deleted.
Description
The command is used to delete the specified setting from the Agilent
81250 System’s database.
Return Value
None
Example
:_test:MMEM:SETT:DEL "TEST1"