SCPI Commands Overview
Overview of the SCPI Command Structure
Agilent 81250 Parallel Bit Error Ratio Tester, Programming Reference, March 2006
59
DeMUX Parameter Commands
The following table lists the commands for setting/getting DeMUX
parameters.
DeMUX Rewiring Commands
The following table lists the DeMUX rewiring commands.
Command (Link to detailed description)
Description
“:INPut:OCOMpensation” on page 214
Sets the decision threshold for sampling the incoming signal.
“:INPut:OCOMpensation?” on page 214
Returns the decision threshold for sampling the incoming signal.
“:TRIGger” on page 215
Sets the source of the clock signal used for the timing of the
E4868A multiplexer or E4869A demultiplexer.
“:TRIGger?” on page 215
Returns the source of the clock signal used for the timing of the
E4868A multiplexer or E4869A demultiplexer.
“:INPut:DELay:SWEep” on page 259
Sets the delay sweep value (only available for the E4969B).
“:INPut:DELay:SWEep?” on page 259
Returns the current delay sweep value (only available for the
E4969B).
“:<Handle>:SGENeral:GLOBal:SYNChronization:REWire” on page 219
Switches the DeMUX rewiring on or off.
“:<Handle>:SGENeral:GLOBal:SYNChronization:REWire?” on
page 219
Returns the current state of the DeMUX rewiring.
“:<Handle>:SGENeral:GLOBal:SYNChronization:RMODe” on page 220
Sets the modes of DeMUX rewiring.
“:<Handle>:SGENeral:GLOBal:SYNChronization:RMODe?” on
page 221
Returns the current mode of DeMUX rewiring.
“:<Handle>:SGENeral:GLOBal:SYNChronization:RCH” on page 221
Switches the rewire verify mode on and off.
“:<Handle>:SGENeral:GLOBal:SYNChronization:RCH?” on page 222
Returns the current rewire verify mode.
“:<Handle>:SGENeral:PDATa:DMUX:STAGe” on page 222
Sets the number of stages of the demultiplexer.
“:<Handle>:SGENeral:PDATa:DMUX:STAGe?” on page 223
Returns the number of stages of the demultiplexer.
“:<Handle>:SGENeral:PDATa:DMUX:STAGe:OUT” on page 223
Sets the number of outputs per demultiplexer for a specified
stage.
“:<Handle>:SGENeral:PDATa:DMUX:STAGe:OUT?” on page 224
Returns the number of outputs per demultiplexer for a specified
stage.
Command (Link to detailed description)
Description
“:<Handle>:SGENeral:GLOBal:SYNChronization:REWire” on page 219
Switches the DeMUX rewiring on or off.
“:<Handle>:SGENeral:GLOBal:SYNChronization:REWire?” on
page 219
Returns the current state of the DeMUX rewiring.
“:<Handle>:SGENeral:GLOBal:SYNChronization:RMODe” on page 220
Sets the modes of DeMUX rewiring.
“:<Handle>:SGENeral:GLOBal:SYNChronization:RMODe?” on
page 221
Returns the current mode of DeMUX rewiring.