Command (Link to detailed description)
Description
“:PULSe:DELay” on page 185
Sets the time from the start of the period to the first edge of the
pulse.
“:PULSe:DELay?” on page 186
Returns the delay value for the specified
port/terminal/connector.
“:PULSe:WIDTh” on page 191
Sets the width (duration) of the pulse.
“:PULSe:WIDTh?” on page 191
Returns the width value for the specified
port/terminal/connector.
“:PULSe:DELay:CYCLes” on page 186
Sets the delay in cycles, where one cycle corresponds to the
actual period/frequency valid for the specified generator output
connector.
“:PULSe:DELay:CYCLes?” on page 187
Returns the number of delay cycles.
“:PULSe:DELay:TIME” on page 188
Sets the delay in seconds.
“:PULSe:DELay:TIME?” on page 188
Returns the delay.
“:PULSe:DCYCle” on page 192
Sets the duty cycle of a repetitive pulse waveform.
“:PULSe:DCYCle?” on page 192
Returns the duty cycle value for the specified
port/terminal/connector.
“:PULSe:HOLD” on page 193
Sets width or duty cycle to hold.
“:PULSe:HOLD?” on page 193
Returns the hold parameter valid for the specified
port/terminal/connector.
“:PULSe:TRANsition[:LEADing]” on page 194
Sets the leading edge value for the specified
port/terminal/connector.
“:PULSe:TRANsition[:LEADing]?” on page 195
Returns the leading edge value for the specified
port/terminal/connector.
“:PULSe:TRANsition:TRAiling” on page 195
Sets the trailing edge value for the specified
port/terminal/connector.
“:PULSe:TRANsition:TRAiling?” on page 196
Returns the trailing edge value for the specified
port/terminal/connector.
“:PULSe:TRANsition:CAConfiguration[:LEADing]” on page 197
Sets the additional leading edge value for the specified
port/terminal/connector, when channel addition mode is active.
“:PULSe:TRANsition:CAConfiguration[:LEADing]?” on page 198
Returns the additional leading edge value for the specified
port/terminal/connector, when channel addition mode is active.
“:PULSe:TRANsition:CAConfiguration:TRAiling” on page 199
Sets the trailing edge value for the specified
port/terminal/connector.
“:PULSe:TRANsition:CAConfiguration:TRAiling?” on page 200
Returns the additional trailing edge value for the specified
port/terminal/connector when channel addition mode is active.
“:MUX” on page 201
SetS the frequency multiply factor for the specified
port/terminal/connector.
“:MUX?” on page 201
Returns the current frequency multiply factor (MUX factor) for
the specified port/terminal/connector.