130
/
184
foreign objects on the surface.
2. Attention to the water tank filling port:
●Special ventilation tooling (gas pressure reducing valve, air gun, sealing tube) is
required for testing.
●After the soaking inspection is completed, the water stains
should be wiped clean in
time.
2.1 Overall leak check
Seal the small tube and ventilate the large tube for air tightness inspection.
2.2 Check of pressure relief valve
Pass 120kPa (1.22 Kgf/cm2, 17.4 psi) compressed air into the big pipe, put the water
filler into the water and let stand for 10 seconds. The small pipe should be free of
bubbles. Increase the compressed air to
130kPa (1.33 Kgf/cm2, 18.9 psi). Bubbles
appear.
3. Auxiliary water tank
First check whether the rubber cover is aging and cracked, if any, replace it. If the
appearance is good, then check the air tightness.
Seal the two small water outlets and open the black plastic cover of the water tank for
air tightness inspection.
Continue to seal the small water outlet, fill the auxiliary tank with water and turn the
auxiliary tank upside down, and observe whether the rubber cover of the water tank
seeps. If there is seepage, it is unqualified. Pour out the water after checking the
tightness, remove the plug and let the auxiliary water tank dry naturally or blow it dry
with a dust blower.
4. Aluminum inlet pipe and aluminum outlet pipe
Check whether the weld is cracked or cracked; check whether the buffer rubber is
aging and cracked. If the appearance is good, then check the air tightness.
Seal one end and ventilate from the other end to check air tightness.
5. Small water tank
Check whether the fan and net cover are firmly assembled, and there should be no jamming of the rotating fan
blades. Check whether the cushion rubber is aging and cracked. Check whether the fan cable is damaged.
Seal one water outlet and ventilate from the other end for air tightness inspection.
The blue of the fan plug is the positive pole, and the black is the negative pole. Find a battery with sufficient power
and connect the wires according to the positive and negative poles, and check whether the fan draws air backwards.
Compressed air with lower air pressure can be blown from the back to the water tank from a long distance to clean
up foreign objects on the surface. Or use a low-pressure water gun to spray the radiating fins from a long distance to
clean up foreign objects on the surface.
Содержание ZT310T-M
Страница 1: ...1 184 ZT310T M Maintenance Manual 2022 01 22 ...
Страница 107: ...107 184 Electrical schematic diagram of EFI system ...
Страница 150: ...150 184 Exploded view of front fork components Directional exploded view ...
Страница 151: ...151 184 Front fork exploded view ...
Страница 152: ...152 184 Exploded view of lower link board ...