114
/
184
2. Starter motor
After the vehicle is
energized, the flameout
switch is hit“ ”
Whether the EFI
fault light is on
N
The flameout
switch of the
right handle is
faulty
Y
Press the start
button
Does the starting
relay respond?
N
Short circuit
relay
Y
Judged as a
starter motor
failure
Check whether
the starter motor
cable is open
Repair the cable
Replace the
starter motor
Does the
starter motor
work?
Y
Relay failure
N
Brake switch or
flameout switch
failure
3. The starter motor runs slowly
Check whether the battery power is insufficient;
Check whether the battery cable connector is in poor contact;
Check whether the starter motor cable is in poor contact;
Check whether the starter motor is abnormal.
4. The starter motor is working normally, but the engine cannot be started
Check whether the starter gear train is faulty;
Check the ignition system for malfunctions.
Ignition system layout
1-Right-handle switch (stop switch, start button) 2-Right-handle secondary switch (to unlock the vehicle) 3-Front disc
brake main pump (front brake switch) 4-Rear disc brake main pump (rear brake switch) 5-Fuse box 6-Battery 7-
Starting relay 8-Starting motor 9-Side bracket flameout switch