Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
90
IM-0883-01
HoldReset
You can finish all sections by [HoldReset] function by external control, shortcut and communication.
This function finish all sections and go to finised section. (See figure below.)
[MultiA/B] function is disable while [HoldReset] is ON.
Change number of section
Section number of multi hold is 4, but you can pseudo change section number by using [HoldReset] and changing
settings. How to reduce of number of section is shown below.
・
Level method, Edge method, Edge timer
(Method 1)
You can finish unnecessary sections speedy by turning "Multi Holding A" or "Multi Holding B" function
ON / OFF at short intervals.
Then, to forbid alarm, set [CompareOutput: None], [CompareAlarmCond.: Outside], [CompJudgeValue:
LowerLimit: -99999, UpperLimit: 99999].
(Method 2)
Use [HoldReset] function to skip unnecessary sections.
・
AutoTimer (You can also execute with EdgeTimer)
(Method 1)
Set [SectionTimer: 0.00sec] to finish unnecessary sections immediately.
(Method 2)
Use [HoldReset] function to skip unnecessary sections.
HoldStartCond.
Set condition of hold starting of each sections.
Set the conditions from the beginning of the section to the start of the hold.
Conditions are shown bolow.
・
Normal
・
Threshld
・
DelayTime
These operations are independent from [SectionSwitch].
To set this function, operate [MENU]
⇒
[Input]
⇒
[MultiA/B S1
~
S4]
⇒
[HoldStartCond.].
Section 1
Peak hold
Section 2
Maximal
hold
Finished section
Finished
section
[MultiHoldA/B]
function
OFF
ON
[HoldReset] function
OFF
ON
Disable