![WATANABE WPMZ-3 Series Скачать руководство пользователя страница 127](http://html2.mh-extra.com/html/watanabe/wpmz-3-series/wpmz-3-series_instruction-manual_3500829127.webp)
Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
126
IM-0883-01
●Behavior of judgement when output mode is “Normal”.
“OutputMode” is “Normal”: Outputs while result is ON.
●Behavior of judgement when output mode is “Latch”.
“OutputMode” is “Latch”: Outputs after result turns on even if result turns off after that.
AL1
AL3
AL4
AL2
AL1
AL2
Compare
Reset
ON
Display value
AL3 Hysterisis
AL4 Hysterisis
AL1 Hysterisis
AL2 Hysterisis
AL1 LessThan
AL2 LessThan
AL3 LessThan
AL4 LessThan
R
es
ul
t
●Behavior of judgement when output mode is “OneShot”.
“OutputMode” is “OneShot”: Outputs ceatain time after result turns on.
AL1
AL3
AL4
AL2
AL2
AL1
AL3 Hysterisis
AL4 Hysterisis
AL1 Hysterisis
AL2 Hysterisis
Display value
AL1 LessThan
AL2 LessThan
AL3 LessThan
AL4 LessThan
R
es
ul
t
AL3
AL4
AL2
AL1
AL3 Hysterisis
AL4 Hysterisis
Al1 Hysterisis
AL2 Hysterisis
AL1 LessThan
AL2 LessThan
AL3 LessThan
AL4 LessThan
Display value
R
e
su
lt