Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
78
IM-0883-01
CreateCompWave
Comparison waveform is made here by editing waveform that is an average of some waveforms that are measured for
standard.
Saved data is 150 points data that is average from 1500 points data, so sharp edge might to be rough.
The flowchart for using waveform compare mode is as follows.
・
RecWaveCapture
Get data for creating reference waveform. Measure waveforms as many times as specified, and create reference
waveform by average the measured data.
Measurement start/cancel is executed by WaveCompA and WaveCompB functions that are operated by external
control and communication function.
How to read of the RefWaveCapture screen is shown below.
Items
Name
Function
①
Wave graph
Display latest waveform (White) and average waveform up to then (Green).
②
Average times
Display (measuring number)/(specified times)
③
Status
READY: Waiting for
WaveCompA or WaveCompB functions
RUN: Measuring
FIN: Finished measuring
*Measurement start/cancel is executed by WaveCompA and
WaveCompB functions that are operated by external control,
shortcut key and communication function.
CompWavePos
*RefWaveCapture: Create a reference waveform by measure some
standard waveforms.
CreateWaveComp: Create a comparison waveform by editing
reference waveform.
CompWavePos: Select a way of comparison
UpperAndLower/UpperOnly/LowerOnly
StartCondition
(Normal
/ Threshold)
v
PatternSelect
You must select same start condition as measurement waveform to
synchronize measurement waveform and comparison waveform.
You need set more items below if you select threshold.
・
Threshold
・
TresholdOnDir
・
TresholdTimeout
・
StartPosition
RefWaveCapture
CreateWaveComp