Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
25
IM-0883-01
MEASUREMENT MODE SWITCHING
This system has “Multi Hold mode” and “Wave Compare mode” besides “Default mode”.
“Multi Hold mode” and “Wave Compare mode” are input signal judgment function.
These modes are switched in “MeasureMode”. ( [Setting]
⇒
[System]
⇒
[General]
⇒
[MeasureMode] )
The input setting changes to a dedicate one for each mode after switching measurement mode.
Please check a table on next page that shows correspondence of each mode and function.
INPUT SETTING DISPLAYS ON EACH MEASUREMENT MODE
【
Multi Hold
】
Hold the inflection point and maximum / minimum points in the caulking process etc. for each specified
section and make a judgment. Up to 4 sections can be specified for the section, and the judgment value can be
set for each hold value.
For details, see the chapter for “Multi Hold mode”.
【
Wave Compare
】
Input signal such as press fitting process is taken in as a waveform, and comparison judgment is carried out
using judgment waveform. Unlike comparative judgment with a single value, good / bad judgment can be
made for the whole process.
For details, see the chapter for “Wave Compare mode”.
*Please set “DispSelect” again after switching measurement mode. ( [Setting]
⇒
[Display]
⇒
[DispSelect] )
* The factory setting is "Default mode”.
* Only one can be activated.
Default
Wave Compare
Muluti Hold