![WATANABE WPMZ-3 Series Скачать руководство пользователя страница 41](http://html2.mh-extra.com/html/watanabe/wpmz-3-series/wpmz-3-series_instruction-manual_3500829041.webp)
Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
40
IM-0883-01
“Diffjudge” operating diagram
*If setting value of [OutputMode] is “Normal”, comparison output coutinues until end of “DetectionInterval”.
*When Compare Reset is ON, comparison output is always set to OFF.
OutputMode
Select comparison output mode.
Please check operation diagram on the previous page about operation of each output mode.
Output mode
Function
Normal
Outputs ON while the condition is satislied.
Latch
Outputs ON until receive reset signal from the condition is
satisfied. Reset signal is controlled by [CompareReset] function
of external control function.
OneShot ## ms
Outputs ON for ## ms from the condition is satisfied.
Operation:[MENU]
⇒
[Output]
⇒
[CompareAL1], [CompareAL2], [CompareAL3], [CompareAL4]
⇒
[OutputMode]
Setting value: Normal(Default), Latch, OneShot5ms, 10ms, 20ms, 50ms, 0.1s, 0.2s, 0.5s, 1s, 2s
OutputLogic
Select output logic of comparison output.
Note that the operation of each output (NPN open collector/PNP open collector/Relay) are different.
Operation:[MENU]
⇒
[Output]
⇒
[CompareAL1], [CompareAL2], [CompareAL3], [CompareAL4]
⇒
[OutputLogic]
Setting value: Negative(Default), Positive
【DetectionInterval】
【DetectionInterval】
Display value
OutputMode
(OneShot)
ON
MAX
MIN
MAX
MIN
(MAX-MIN)
(MAX-MIN)
OutputMode
(Latch)
ON
OFF
OFF
ON
OFF
OutputMode
(Normal)
Compare
Reset
Function ON