Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
127
IM-0883-01
ZoneJudge
Determine the inclusion relation with the two comparison judgment values.
Below, the comparison output operation is shown for each output mode.
1
)
In case of OnCondition is InTheZone.
Comparison output turns on when display value is inside of the zone.
●Behavior of judgement when output mode is “Normal”.
“OutputMode” is “Normal”: Outputs while result is ON.
Zone hysterisis
Display value
Zone upper limit
Zone hysterisis
Zone lower limit
AL2
AL1
R
e
su
lt
AL1 Zone
Zone hysterisis
Zone upper limit
Zone hysterisis
Zone lower limit
AL2 Zone
AL1
AL2
●Behavior of judgement when output mode is “Latch”.
“OutputMode” is “Latch”: Outputs after result turns on even if result turns off after that.
Zone hysterisis
Display value
Zone upper limit
Zone hysterisis
Zone lower limit
AL2
AL1
R
es
ul
t
AL1 Zone
Zone hysterisis
Zone upper limit
Zone hysterisis
Zone lower limit
AL2 Zone
Compare
Reset
ON
Output
OnCondition
Comparison condition
Result
AL1
InTheZone
Upper limit of AL1
≧
Display value
≧
Lower limit of
AL1
AL1
AL2
Upper limit of AL2
≧
Display value
≧
Lower limit of
AL2
AL2
AL3
Upper limit of AL3
≧
Display value
≧
Lower limit of
AL3
AL3
AL4
Upper limit of AL4
≧
Display value
≧
Lower limit of
AL4
AL4