Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
89
IM-0883-01
EdgeTimer
Next section starts after [MultiA/B] function ON and finish after set time.
From the end of the section until the next [MultiA/B] function is an interval and display last hold value. If there is no
hold value even once in last section, display present value in interval.
Immediately start the next section if [MultiA/B] function is ON in the middle of a section. (See Section 3, 4 in the
figure below)
AutoTimer
Start first section after [MultiA/B] function ON.
After set time, the section finishes and next section starts immediately.
No interval exists between sections.
Section 1
Peak hold
Section 2
Maximal
hold
Section 3
Inflection hold
Section 4
Maximal
hold
Finished
section
Finished
section
[MultiHoldA/B]
function
OFF
ON
Section 1
Peak hold
Section 2
Maximal
hold
Section 3
Inflection
hold
Section 4
Maximal
hold
Finished
hold
Finished
setion
[MultiHoldA/B]
function
OFF
ON