Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
74
IM-0883-01
You can erase logged data by [Diag/Log]
⇒
[AlarmLogClear].
This screen is displayed and you can clear all of data by operationg [Yes].
Setting Items
Settings related alarm logare shown below.
SyncedAlarm
Select automatically save with ON of each alarms 1
~
4.
Operation:[MENU]
⇒
[System]
⇒
[AlarmLog]
⇒
[SyncedAlarm]
Setting:
AL1 ON / OFF (Initial state is ON)
AL2 ON / OFF (Initial state is ON)
AL3 ON / OFF (Initial state is ON)
AL4 ON / OFF (Initial state is ON)
RecordPos
Select a timing of saving data after alarm occurs.
・
BeforeAlarm: Save log when the data before alarm occurs occupies 80% in screen. (Save data of red frame
below.)
・
BeforeAndAfter: Save log when the data before alarm occurs occupies 50% in screen. (Save data of red frame
below.)
AL1
ON
80%
20%
AL1
ON
50%
50%