Graphical Digital Panel Meter WPMZ-3 INSTRUCTION MANUAL
46
IM-0883-01
10.
OUTPUT ADVANCED SETTING
Here, the items of output setting which are not explained in the “BASIC SETTING” are explained.
Since the output options differ depending on the model, the items that can be set change depending on the model.
The correspondence between model number and output option is as follows.
・
WPMZ-3-□□□-X□-□□□: No output
・
WPMZ-3-□□□-1□-□□□:
Analog output
・
WPMZ-3-□□□-2□-□□□:
BCD output(open collector NPN)
・
WPMZ-3-□□□-3□-□□□:
BCD output(open collectorPNP)
・
WPMZ-3-□□□-4□-□□□:
RS-232C
・
WPMZ-3-□□□-5□-□□□:
RS-485(Modbus RTU)
CompareAL1~4
ActCondition
Select the condition of comparison output function.
Operation:[MENU]
⇒
[Output]
⇒
[CompareAL1], [CompareAL2], [CompareAL3], [CompareAL4]
⇒
[ActCondition]
Setting value: Always(Default)
ExceptNearZero *
OnStable *
OnStableExceptNearZero*
OnHold
*Please also set “ZeroArea”, “StableArea”, “StableTime” of input setting.
OnDelay
This is a delay function that comparison output turns ON when the comparison condition is kept continuously
for the set time or more.
Operation:[MENU]
⇒
[Output]
⇒
[CompareAL1], [CompareAL2], [CompareAL3], [CompareAL4]
⇒
[OnDelay]
Setting value:
None(Default),20ms,50ms,100ms,200ms,500ms,1s,5s,10s,20s,
OffDelay
This is a delay function that comparison output turns OFF when the comparison condition is kept continuously
for the set time or more.
Operation:[MENU]
⇒
[Output]
⇒
[CompareAL1], [CompareAL2], [CompareAL3], [CompareAL4]
⇒
[OffDelay]
Setting value:
None(Default),20ms,50ms,100ms,200ms,500ms,1s,5s,10s,20s,