Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 198
Subject to Export Control. See Cover Page for details.
September 2021
5.13.2
DO-260 TEST SINGLE ADS-B EXAMPLE
5.13.2.1
The following example creates a normal test for a single ADS-B.
:RGS:SCE:VDB:1:RANGE 5
//ALTITUDE By Default, No valid for ATCRBS & TIS-B
:RGS:SCE:VDB:1:RPLYANT BOTTOM
:RGS:SCE:VDB:1:RPLYPWR -20
//Binary By Default, No valid for ATCRBS (ignored)
:RGS:SCE:VDB:1:AMODE BINARY
:RGS:SCE:VDB:1:VELOCITY 150
:RGS:SCE:VDB:1:VERTICAL 0
:RGS:SCE:VDB:1:TRACK 0
:RGS:SCE:VDB:1:DATA 007FE001FF
:RGS:SCE:VDB:1:AMPLITUDE 008403105000000000000000000000
Video Data Block Definition Example #2
:RGS:SCE:VDB:2:MODE ATCRBS
:RGS:SCE:VDB:2:ENABLE ON
:RGS:SCE:VDB:2:BEGIN 0
:RGS:SCE:VDB:2:END 3000
//ALTITUDE & FORWARD By Default
:RGS:SCE:VDB:2:WS:1:RPLYANT BOTTOM;:RPLYQUAD FORWARD
:RGS:SCE:VDB:2:RPLYCH 1
:RGS:SCE:VDB:2:ALTITUDE 12000
:RGS:SCE:VDB:2:BEARING 135
:RGS:SCE:VDB:2:RANGE 5
:RGS:SCE:VDB:2:RPLYPWR -20
:RGS:SCE:VDB:2:VELOCITY 150
:RGS:SCE:VDB:2:VERTICAL 0
:RGS:SCE:VDB:2:TRACK 0
:RGS:SCE:VDB:2:DATA FFFFE003FFE
:RGS:SCE:VDB:2:AMPLITUDE 000000000000000000000
//BEGIN TEST
//RESET DO260 TEST
:RGS:DO260:RESET
//TEST DEFINITION
//TIMING DEFINTION
:RGS:DO260:TIMING:TRIGGER:SOURCE GENA
//0-DELAY+ 1-DELAY- 2-RANDOM
:RGS:DO260:TIMING:TRIGGER:MODE 0
:RGS:DO260:TIMING:PERIOD 10