Operation,
Operating Procedures and Test Configurations
1-2-4
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 14
Subject to Export Control. See Cover Page for details.
September 2021
4.1.14
SET UP A STATIC MODE S EXTENDED INTRUDER
STEP
PROCEDURE
1
Go to the
H o m e S c r e e n
.
2
Select the
T C A S
Softkey to display the TCAS Home Screen.
3
Select the
S c e n a r i o
Softkey to display the TCAS Scenario Screen.
4
Use the
S c e n a r i o T i m e
Field or Settings Softkey to enter the scenario time.
5
Set the number of static intruders to at least 1 using the
N u m b e r o f S t a t i c I n t r u d e r s
Field or
Settings Softkey.
6
Select the
I n t r u d e r s
Softkey to edit the intruder information. Select Mode S Extended in the
I n t r u d e r M o d e
Field or Settings Softkey to display the Static Mode S Extended Screen.
7
If more than 1 Intruder is being defined, select the intruder to be defined from the Number Field
on the Intruders Screen.
8
Use the controls on the Static Mode S Extended Screen to enter the information for the Mode S
Extended intruder.
Static Mode S Extended Minimum Parameters
Parameter
Default
Selectio n (Ran ge)
Tx Channel
Gen A
Gen A, Gen C or Gen D
Altitude
1000
-1000 to 126700 feet
Bearing
0
0
to 359
Range
0
0 to 160 nmi
Latitude
-90
t o 90
Longitude
-180
to 180
Velocity
0
0 to 2000 knots
Vertical Speed
0
32576 t o 32576 ft/ min
Track
0
-180
to 180
Reply Power
-20
Low Power
-90 to -20 dBm
High Power
- 69 to 1 dBm
Reply Antenna
By Altitude
Bottom, Top, Both, Alternating
or By Altitude
Squitter Power
-50
Low Power
-90 to -20 dBm
High Power
- 69 to 1 dBm
Squitter Antenna
Both
Top, Bottom or Both
Star ting at
0
0 to Scenario Duration
Stopping at
Scenario Duration
0 to Scenario Duration
Enable
Enable
Enable/Disable
Reply
ON
ON/OF F
Squitt er
ON
ON/OF F
Ground
OFF
ON/OF F
DO -260 Mode
DO-260
DO-260, DO-260A or
DO-260B
Cr osslink Capability
OFF