![Viavi 113956 Скачать руководство пользователя страница 528](http://html1.mh-extra.com/html/viavi/113956/113956_operation-manual_1011843528.webp)
Specifications, Chapter 3 - Specifications
Suppressor Pulse (xpdr)
, Width
1-3-1
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 14
Subject to Export Control. See Cover Page for details.
September 2021
8.
SUPPRESSOR PULSE (XPDR)
8.1
WIDTH
Duration of transmission
8.2
POSITION
3.4
0.3
s prior to P1 of interrogation
8.3
LEVEL
> 25V
9.
SPECTRUM ANALYZER PORTS (MOD STRIKE 4 REQUIRED)
Insertion Loss (Antenna Ports to Spectrum Analyzer Outputs):
SA AMP:
-31 dB
5 dB
SA Thru:
-59.5 dB
5 dB
10. PHYSICAL
Overall Dimensions:
10.5 in (H) X 19 in (W) X 24 in (D)
(26.7 cm, 48.3 cm, 60.9 cm)
Weight:
43 lbs. (19.5 kg)
11. AC INPUT POWER
Voltage Range:
100 to 240 VAC at 60 to 50 Hz
Power Consumption:
150 W typical
12. ENVIRONMENTAL
Temperature:
Full Specified Performance
23
C (
5
C)
Operating:
0
C to 40
C
Storage
0
C to 71
C
Relative Humidity:
0 to 95% non-condensing
Degree of Protection:
IPX-0
13. COMPLIANCE
CE
UL/EN61010-1
EN 61326-1
MIL-PRF-28800F (Class 3 Device)