Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 25
5.7.1.5
Record
ATCRBS Replies/ Interrogations:
Bit 7 (MSB): UUT: Top Receiver = 1, Bottom Receiver = 0; RGS: Always 0
Bit 6 to 4: UUT: Always 0; RGS: Transmitter
Transmitter
Code
Generator A
0
Generator B
1
Generator C
2
Generator D
3
Generator E
4
Generator F
5
Bit 3-0: Always 0
Byte 17 to 19: Address
Mode S Replies/Interrogations:
Mode S Address (Byte 17, Bit 7 to MSB)
ATCRBS Replies/Interrogations:
All 0’s
Byte 20 to 25: Time Stamp
6 bytes represent time from start of scenario. Bit resolution is equivalent to
25 ns.
Example:
:RGS:RCV:LOG:DL?\r
Returns:
070000000000000020000000E6025D0555555501DF128460FB
Command Syntax:
{:RGS | :RGS2000NG}{:RCV | :RCVR}{:REC | :RECORD}SP{ON | OFF}CR
Description:
This command enables or disables the Unit from recording (logging) the
messages being received by the receivers that are enabled to capture.
Default:
Off
Example:
:RGS:RCV:REC ON\r