3.5.4.4
Single Interrogation Test Interference Pulse Screen
This user screen is used to define an interference pulse. The first pulse is set in reference to the top P1
pulse in a single interrogation and the first interrogation in a double interrogation. The second
interference pulse needs to be enabled to be transmitted.
SCREEN SEQUE NCE:
Transponder Screen > Transponder Test Softkey > Test Mode: Single Interrogation > Interference
Pulse Softkey
F i g u r e 1 .2 . 3 - 1 0 9 T r an s p o n d er I n t e r f e r e n c e P u l s e S c r e e n
Screen Components
Descriptio n
Pulse Spacing Field
Selects the Pulse Spacing. Parameters can also be defined
using the Pulse Spacing Softkey Menu.
P1-P2 Pulse Spacing is enabled on the Pulse Spacing Softkey
Menu.
Pulse Width Field
Defines the Pulse Width for P1, P2 and P3. Parameter can also
be defined using the Pulse Width Softkey Menu.
P1/P2 Pulse Menu
Selects the interference pulse mode used for the interference
pulse. When VAR is selected the Pulse Level Field is enabled
which allows the user to define a specific value in dB.
Pulse Level (Power Dev) Field
Defines the interference pulse amplitude for P1 and P2.
Parameter can also be defined using the Pulse Level Softkey
Menu.
Reset Softkey
Pressing this softkey resets current screen settings to default