5.11.17.3.11
Table Entry Side Lobe Suppression (SLS)
5.11.17.3.12
Table Entry Synchronization
5.11.17.4
Single Interrogation
This set of commands allows the user to define single ATCRBS or Mode S interrogations.
5.11.17.4.1
Antenna Power Deviation
Command Syntax:
{:RGS | :RGS2000NG}{:XPDR}{:ITABLE:}<table entry>{:SLS}SP{ON |
OFF}CR
Description:
This command turns on or off SLS (P2) pulse in an ATCRBS interrogation of
the selected table entry.
Table Entry:
1 to 1000 (decimal ASCII)
Default:
Off
Example:
:RGS:XPDR:ITABLE:1:SLS ON\r
Query:
:RGS:XPDR:ITABLE:1:SLS?\r
Return:
ON
Command Syntax:
{:RGS | :RGS2000NG}{:XPDR}{:ITABLE}{:SYNC}SP<numeric>CR
Description:
This command allows selecting the table entry for synchronization. The
measured UUT values are obtained from the reply associated with the
interrogation selected for synchronization.
Numeric:
1 to 32 (decimal ASCII)
Default:
1.
Example:
:RGS:XPDR:ITABLE:SYNC 2\r
Query:
:RGS:XPDR:ITABLE:SYNC?\r
Return:
2
Command Syntax:
{:RGS | :RGS2000NG}{:XPDR}{:ANT | :ANTENNA}{:POW |
:POWER}SP<numeric>[,<numeric1>]CR
Description:
This command sets the antenna power deviation between the top and
bottom antenna. The optional <numeric1> is ignored if the interrogation
mode is not “Alternate Mode A/Mode C.” For “Alternate Mode A/Mode C”,
the <numeric> is used to define the Mode A pulse and the <numeric1> is
used to define the Mode C pulse.
Numeric:
0 to -20 dB (decimal ASCII)
Default:
0
Example:
:RGS:XPDR:ANT:POW -3\r
Query:
:RGS:XPDR:ANT:POW?\r
Return:
-3.0
Example:
(Alternate Mode A/Mode C)
:RGS:XPDR:ANT:POW -3,-4\r
Query:
:RGS:XPDR:ANT:POW?\r
Return:
-3.0,-4.0