Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 79
5.9.4.15
Mode
5.9.4.16
Mode-S All Call Reply (DF=11) Message
DF11 squitter is transmitted by the Unit at a rate of 1.0 second.
Dynamic intruders (targets) allow definition of multiple time intervals where the DF11 squitter can be
enabled or disabled.
Static intruders (targets) allow the user to enable or disable the DF11 squitter for the entire scenario.
5.9.4.16.1
Mode-S All Call Reply (DF=11) Message Schedule
5.9.4.16.1.1
Dynamic DF=11 Schedule
5.9.4.16.1.1.1 Interval Enable
5.9.4.16.1.1.2 Interval Quantity
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:MOD | :MODE}SP{ATCRBS | TCAS | TIS-B |
EXTENDED | ADS-R}CR
Description:
This command sets the selected intruder to a specific intruder type. The
intruder types are ATCRBS, TCAS (Mode S Only), TIS-B, Mode S Extended
or ADS-R. When the intruder type is set to ADS-R, the Control Field (CF) is
set with the value 6 automatically.
Default:
TCAS
Example:
:RGS:SCE:STAT:2:MOD ADS-R\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:DYN: | :DYNAMIC:}<intruder
number>{:SDF11}{:INT: | :INTERVAL:}<interval number>{:ENA |
:ENABLE}SP{ON | OFF}CR
Description:
This command enables or disables the DF11 squitter message of the
specified intruder.
Default:
On
Example:
:RGS:SCE:DYN:1:SDF11:INT:2:ENA ON\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:DYN: | :DYNAMIC:}<intruder
number>{:SDF11}{:NINT | :NINTERVALS}SP<numeric>CR
Description:
This command sets the number of DF11 squitter message intervals for the
selected intruder.
Numeric:
0 to 255 (decimal ASCII)
Default:
By default, the spaces not defined between intervals are consid ered off.
Example:
:RGS:SCE:DYN:1:SDF11:NINT 4\r
NOTE: