Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 193
Intruder UF0 Definition Example #1
//no valid for ATCRBS & TIS-B
:RGS:SCE:STATIC:1:UF0:NINTERVALS 2
:RGS:SCE:STATIC:1:UF0:INTERVAL:1:BEGIN 0
:RGS:SCE:STATIC:1:UF0:INTERVAL:1:END 30
:RGS:SCE:STATIC:1:UF0:INTERVAL:1:ENABLE ON
:RGS:SCE:STATIC:1:UF0:INTERVAL:1:RL 0
:RGS:SCE:STATIC:1:UF0:INTERVAL:1:AQ 0
//0 By Default, hexadecimal, [0,0xFF]
:RGS:SCE:STATIC:1:UF0:INTERVAL:1:BDS 0A
:RGS:SCE:STATIC:1:UF0:INTERVAL:2:BEGIN 30; :INTERVAL:2:END 60; :INTERVAL:2:ENABLE ON;:RL
0;:AQ
0;:BDS 08
Static Intruder Definition Example #2
:RGS:SCE:STATIC:2:MODE TIS-B
:RGS:SCE:STATIC:2:ENABLE ON
:RGS:SCE:STATIC:2:BEGIN 0
:RGS:SCE:STATIC:2:END 3000
:RGS:SCE:STATIC:2:MSADDR 2
:RGS:SCE:STATIC:2:GROUND OFF
:RGS:SCE:STATIC:2:PPSQ 1
//0 By Default, [0,2], 1-GenA 2-GenC 3-GenD
:RGS:SCE:STATIC:2:RPLYCH 1
:RGS:SCE:STATIC:2:ALTITUDE 12000
:RGS:SCE:STATIC:2:BEARING 135
:RGS:SCE:STATIC:2:RANGE 5
:RGS:SCE:STATIC:2:RPLYANT ALTITUDE
:RGS:SCE:STATIC:2:SQANT BOTH
:RGS:SCE:STATIC:2:SQPWR -50
:RGS:SCE:STATIC:2:RPLYPWR -20
:RGS:SCE:STATIC:2:VELOCITY 150
:RGS:SCE:STATIC:2:VERTICAL 0
:RGS:SCE:STATIC:2:TRACK 0
:RGS:SCE:STATIC:2:CA 0
:RGS:SCE:STATIC:2:UM 0
:RGS:SCE:STATIC:2:DR 0
:RGS:SCE:STATIC:2:FS 0
:RGS:SCE:STATIC:2:VELTYPE 0
:RGS:SCE:STATIC:2:IDENT STAT002
//1 By Default, [1,4], valid only for Extended & TIS-B
:RGS:SCE:STATIC:2:IDENTTYPE 1
//0 By Default [0,7], No Valid for ATCRBS (ignored)