Page 123
F i g u r e 1 .2 . 3 - 1 0 7 T r an s p o n d er S i n g l e In t e r r o g a t i o n ( M o d e S ) S cre e n
Screen Components
Descriptio n
Mode Menu
Selects the type of interrogation to be performed. This field is
linked to the Interrogation Type on the Transponder Test Screen.
PRF Field
Defines the pulse repetition rate (Pulse Repetition Frequency).
Power Field
Defines the Power.
Frequency Field
Defines the frequency.
PRF Sync
Allows the user to sync the PRF of the first transmission with the
second. Only available for P1-P2, Pulse or DME interrogations.
Pulse Spacing Fields
Defines the Pulse Spacing. Parameter can also be defined using
the Pulse Spacing Softkey Menu.
Pulse Width Fields
Defines the Pulse Width for P1, P2 and P3. Parameter can also
be defined using the Pulse Width Softkey Menu.
Pulse Level (Power Dev) Fields
Selects the Pulse Level (Power Dev) for P1, P2 and P3.
Parameter can also be defined using the Pulse Level Softkey
Menu.
Power Dev Field
Defines the Antenna Power Deviation between the top and
bottom antenna.
Time Field
Defines the Antenna Time Deviation between the top and bottom
antenna.
SLS Toggle Switch
Turns the Side Lobe Suppression (SLS) pulse on the SUPP
Connector ON or OFF.
Interrogation Fields
Displays message data for the selected table entry.
Reply Information Fields
These fields display data contained in the intruder reply
message.
Reset Softkey