Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 80
Subject to Export Control. See Cover Page for details.
September 2021
5.9.4.16.1.1.3 Interval Start Time
5.9.4.16.1.1.4 Interval Stop Time
5.9.4.16.2
Static DF=11 Schedule
5.9.4.16.2.1
Interval Enable
5.9.4.17
Mode S Data Parameters
5.9.4.17.1
Crosslink Capability (CC)
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:DYN: | :DYNAMIC:}<intruder
number>{:SDF11}{:INT: | :INTERVAL:}<interval
number>{:BEGIN}SP<numeric>CR
Description:
This command sets the start time for the selected DF11 squitter message
interval for the selected intruder.
Numeric:
0 to 6550 seconds (decimal ASCII) (Resolution 0.1)
Default:
By default, the spaces not defined between intervals are consid ered off.
Example:
:RGS:SCE:DYN:1:SDF11:INT:2:BEGIN 12.5\r
NOTE:
Only the user can define the intervals where the message is transmitted.
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:DYN: | :DYNAMIC:}<intruder
number>{:SDF11}{:INT: | :INTERVAL:}<interval
number>{:END}SP<numeric>CR
Description:
This command sets the stop time for the selected DF11 squitter message
interval for the selected intruder.
Numeric:
0 to 6550 seconds (decimal ASCII) (Resolution 0.1)
Default:
By default, the spaces not defined between intervals are consid ered off.
Example:
:RGS:SCE:DYN:1:SDF11:INT:2:END 40.5\r
NOTE:
Only the user can define the intervals where the message is transmitted.
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: |
:STATIC:}<intruderno>{:SDF11}{:ENA | :ENABLE}SP{ON | OFF}CR
Description:
This command enables or disables the DF11 squitter message of the
specified intruder.
Default:
On
Example:
:RGS:SCE:STAT:1:SDF11:ENA ON\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:CC}SP{ON | OFF}CR
Description:
This command either enables or disables crosslink capability Bit for the
specified intruder.
Default:
Off
Example:
:RGS:SCE:STAT:2:CC ON\r