Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 40
Subject to Export Control. See Cover Page for details.
September 2021
5.8.10.1
Trigger Parameters
5.8.10.2
Mode
5.8.10.3
Source
5.8.10.4
Random Position Width
Command Syntax:
{:RGS | :RGS2000NG}{:DO260}{:TIMING}{:TRIGGER |
:TRIG}{:MODE}SP<numeric>CR
Description:
This command sets the trigger mode.
Delay+ delays positively all the enabled generators according with each
delay amount from the trigger source.
Delay- delays all the enable generators negatively.
Random alters the start of all the enable generators from transmission to
transmission in the range specified.
Walk moves the starting position of the enable generators from the initial
delay by 50 ns every transmission.
Numeric:
0 to 3
Value
Mode
0
Delay+
1
Delay-
2
Random
3
Walk
Default:
0 (Delay +)
Example:
:RGS:DO260:TIMING:TRIG:MODE 0\r
Command Syntax:
{:RGS | :RGS2000NG}{:DO260}{:TIMING}{:TRIGGER |
:TRIG}{:SOURCE}SP{GENA | GENB | GENC | GEN D | GENE | GENF}CR
Description:
This command sets the generator trigger source.
In Low Power Mode, all generators are available.
In High Power Mode, only the gen erators GENA, GENC and GENE are
available
Default:
Gen A
Example:
:RGS:DO260:TIMING:TRIG:SOURCE GENA\r
Command Syntax:
{:RGS | :RGS2000NG}{:DO260}{:TIMING}{:TRIGGER |
:TRIG}{:RANDOM}{:WIDTH | :WID}SP<numeric>CR
Description:
This command sets the width in ns of the random pulse.
Numeric:
0 to 120000 ns (decimal ASCII).
Default:
120000 ns
Example:
:RGS:DO260:TIMING:TRIG:RANDOM:WID 1200\r
NOTE: