Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 76
Subject to Export Control. See Cover Page for details.
September 2021
5.9.4.12.3
Delta Enable
5.9.4.12.4
Delta Range
5.9.4.13
ICAO/Mode A Flag
5.9.4.14
Identification Message
This set of commands allows the user to define the Identification Squitter for the specified intruder
(target).
5.9.4.14.1
Identification Message Parameters
5.9.4.14.1.1
Emitter Category
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:HYBRID}{:ENABLE | :ENA}SP{ON | OFF}CR
Description:
This command enables or disables hybrid delta altitude, range a nd bearing.
Default:
Off
Example:
:RGS:SCE:DYN:2:HYBRID:ENA ON\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:HYBRID}{:DRAN |
:DRANGE}SP<numeric>CR
Description:
This command sets the delta range for hybrid testing. The passive position
squitter is modified from the actual by the delta range.
Numeric:
-12000 to 12000 feet (decimal ASCII)
Default:
0 nmi
Example:
:RGS:SCE:DYN:2:HYBRID:DRAN 1250\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:IMF}SP <numeric>CR
Description:
This command sets the type of identity associated with the aircraft data
reported in the TIS-B message. IMF equal to zero indicates the TIS-B data
is identified by an ICAO-24 Bit aircraft address. IMF equal to one indicates
the TIS-B data is identified by a Mode A Code.
Numeric:
0 to 1 (decimal ASCII)
Default:
0
Example:
:RGS:SCE:DYN:2:IMF 1\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:IDENTEC}SP <numeric>CR
Description:
This command sets the selected intruder emitter category for the Ident
squitter.
Numeric:
0 to 7 (decimal ASCII)
Default:
0
Example:
:RGS:SCE:DYN:1:IDENTEC 2\r