Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 43
5.9.2.4
1030 Message Block Message Channel
5.9.2.5
1030 Message Block Message Type
5.9.2.6
1030 Message Block Message Data
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:I1030:}<message
number>{:TXCH}SP<numeric>CR
Description:
This command sets the 1030 message to reply on the specified generator.
Numeric:
Value
Generator
1
1030RX
Example:
:RGS:SCE:I1030:1:TXCH 1\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:I1030:}<message
number>{:TYPE} SP<numeric>CR
Description:
This command sets the type of the 1030 message selected.
Numeric:
Value
Generator
1
Mode S Interrogation
2
Mode A
3
Mode C
4
Mode A All Call
5
Mode C All Call
6
Mode A/Mode S All Call
7
Mode C/Mode S All Call
Example:
:RGS:SCE:I1030:1:TYPE 4\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:I1030:}<message
number>{:MESS: | :MESSAGE} SP<numeric>CR
Description:
T h i s c o m m a n d s e t s t h e d a t a m e s s a g e f o r t h e s e l e c t e d 1 0 3 0
m e s s a g e .
Numeric:
Short interrogation 0 - FFFFFFFFFFFFFF (14 hexadecimal ASCII)
Long interrogation 0 – FFFFFFFFFFFFFFFFFFFFFFFFFFFF (28
hexadecimal ASCII)
The last six characters are the Mode S Address.
Example:
:RGS:SCE:I1030:1:MESS 5A5A5A5A000002\r