3.4.25
TCAS MODE S PULSE INFORMATION SCREEN
Allows the user to modify the width, position, amplitude and visibility of the Mode S Preamble pulses for
a selected Generator a nd allows changing the rise and fall times for the selected Generator.
SCREEN SEQUE NCE:
TCAS Scenario Screen > Mode S Pulse Information Softkey
F i g u re 1 . 2 . 3 - 9 8 T C A S M o d e S P u l s e I n f o r m a t io n Sc r e e n
Screen Components
Description
Tx Channel Menu
Selects the Tx Channel. Tx Channels are defined on the TCAS Settings
user Screen. Refer to Section
Rise/Fall Field
Defines the rise and fall time for the selected Generator.
Delta Width (ns) Field
Defines the Delta Width for the selected Generator.
Delta Position (ns) Field
Defines the Delta Position for the selected Generator.
Delta Amplitude (ns) Field
Defines the Delta Amplitude for the selected Generator.
Enable
Enables/disables the Generator.
Reset Softkey
Pressing this softkey resets values back to the Factory default settings.
“XX” Pulse Softkeys
Accesses a settings softkey menu for the selected pulse type.