Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 67
5.9.4.4
Altitude Reporting
5.9.4.5
ATCRBS Parameters
5.9.4.5.1
Altitude Mode
5.9.4.5.2
Mode A Code
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:ALTRPT}SP{ON | OFF}CR
Description:
This command sets the altitude reporting for the selected intruder on or off.
If set to off:
Mode C
Intruder replies to an ATCRBS interrogation with only the framing pulses (F1
and F2).
Mode S Extended, TIS-B or ADS-R
Altitude data is not available. For example, DF0 contains all zero in Altitude
Code.
Default:
On
Example:
:RGS:SCE:STAT:2:ALTRPT ON\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:AMODE}SP{GILHAM | BINARY}CR
Description:
This command sets the altitude data mode to either Gilham or Binary.
Numeric:
Altitude Binary Mode: -1000 to 50175 feet in 25 feet resolution
Altitude Gilham Mode: -1000 to 126700 feet in 100 feet resolution
Default:
Binary
Example:
:RGS:SCE:STAT:2:AMODE GILHAM\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:ACODE}SP<numeric>CR
Description:
This command sets the Mode A code.
Numeric:
0 to 7777 (octal ASCII)
Default:
0000
Example:
:RGS:SCE:STAT:2:ACODE 6532\r