![Viavi 113956 Скачать руководство пользователя страница 420](http://html1.mh-extra.com/html/viavi/113956/113956_operation-manual_1011843420.webp)
Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 148
Subject to Export Control. See Cover Page for details.
September 2021
5.9.9.18
Resolution
5.9.9.19
Start Time
5.9.9.20
Stop Time
5.9.9.21
Track
5.9.9.22
Trigger Mode
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:VDB}{:RES |
:RESOLUTION}SP{25 | 50}CR
Description:
This command allows setting the resolution of the video data block Bits to
25 or 50 ns.
Default:
50 ns (Reset command returns setting back to 50 ns).
Example:
:RGS:SCE:VDB:RES 25\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:VDB:}<vdb
number>{:BEGIN}SP<numeric>CR
Description:
This command allows setting the start time of the selected VDB.
Numeric:
0 to 6550 seconds (decimal ASCII)
Default:
0
Example:
:RGS:SCE:VDB:1:BEGIN 6\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:VDB:}<vdb
number>{:END}SP<numeric>CR
Description:
This command allows setting the stop time of the selected VDB.
Numeric:
0 to 6550 seconds (decimal ASCII)
Default:
Scenario end time.
Example:
:RGS:SCE:VDB:1:END 28\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:VDB:}<vdb
number>{:TRACK}SP<numeric>CR
Description:
This command allows setting th e track of the selected VDB.
Numeric:
-180 to 180 degrees (decimal ASCII)
0 to 360 degrees (decimal ASCII)
Default:
0 degrees
Example:
:RGS:SCE:VDB:1:TRACK 90\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:VDB:}<vdb
number>{:MODE}SP{TCAS | ATCRBS}CR
Description:
This command allows setting if the selected VDB triggers from an ATCRBS
or TCAS (Mode S) interrogation.
Default:
TCAS
Example:
:RGS:SCE:VDB:1:MODE ATCRBS\r