Dynamic Intruder Definition Example #2
//Dynamic Intruder Number 2
:RGS:SCE:DYNAMIC:2:MODE ATCRBS
:RGS:SCE:DYNAMIC:2:ENABLE ON
:RGS:SCE:DYNAMIC:2:BEGIN 0
:RGS:SCE:DYNAMIC:2:END 3000
//ALTITUDE & FORWARD By Default
:RGS:SCE:DYNAMIC:2:WS1:1:RPLYANT ALTITUDE;:RPLYQUAD FORWARD
:RGS:SCE:DYNAMIC:2:WS2:2:RPLYANT ALTITUDE;:RPLYQUAD FORWARD
:RGS:SCE:DYNAMIC:2:PPRPLY 1
:RGS:SCE:DYNAMIC:2:RPLYCH 1
:RGS:SCE:DYNAMIC:2:ALTITUDE 12000
:RGS:SCE:DYNAMIC:2:BEARING 135
:RGS:SCE:DYNAMIC:2:RANGE 5
:RGS:SCE:DYNAMIC:2:RPLYPWR -20
:RGS:SCE:DYNAMIC:2:VELOCITY 150
:RGS:SCE:DYNAMIC:2:VERTICAL 0
:RGS:SCE:DYNAMIC:2:TRACK 0
//0000 By Default, Octal Digits, PadLeft(4, '0'), only valid for ATCRBS (ignored for rest)
:RGS:SCE:DYNAMIC:2:ACODE 1234
//ON By Default, only valid for ATCRBS (ignored for the rest)
:RGS:SCE:DYNAMIC:2:ALTRPT ON
Interrogator (Ground Station) Definition Example #1
//Interrogator Number 1
//UF4 By Default, {4,5, 11, 16, 20, 21}
:RGS:SCE:INTERROGATOR:1:UF UF4
//ON By Default
:RGS:SCE:INTERROGATOR:1:ENABLE ON
//0 By Default, [0, Scenario Time]
:RGS:SCE:INTERROGATOR:1:BEGIN 0
//Scenario Time By Default, [0, Scenario Time], stop >= start
:RGS:SCE:INTERROGATOR:1:END 200
//0 By Default,
:RGS:SCE:INTERROGATOR:1:NINTERVALS 2
//0 By Default, [Interrogator Start, Interrogator Stop]
:RGS:SCE:INTERROGATOR:1:INTERVAL:1:BEGIN 0
//Interrogator Stop Time, [Interrogator Start, Interrogator Stop], stop >= start
:RGS:SCE:INTERROGATOR:1:INTERVAL:1:END 30
//ON By Default
:RGS:SCE:INTERROGATOR:1:INTERVAL:1:ENABLE ON
//20000000 By Default, hexadecimal digits, exclude P/AP
:RGS:SCE:INTERROGATOR:1:INTERVAL:1:MESSAGE 20000000