Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 77
5.9.4.14.1.2
Identification
5.9.4.14.1.3
Identification Type
5.9.4.14.2
Identification Message Schedule
Identification squitter is transmitted by the Unit at a rate of 5.0 seconds.
Dynamic intruders (targets) allow definition of multiple time intervals where the Iden tification squitter
can be enabled or disabled.
Static intruders (targets) allow the user to enable or disable the Identification squi tter for the entire
scenario.
5.9.4.14.2.1
Dynamic Identification Schedule
5.9.4.14.2.1.1 Interval Enable
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:IDENT}SP{<characters>| BLANK |
NODATA}CR
Description:
This command sets the selected intruder identification characters for the
Ident squitter. The maximum length is eight characters (use the keyword
“BLANK” to define al l blank characters).
Default:
Static intruders are STAT001, STAT002, ….
Dynamic intruders are DYN01, DYN02,…
Example:
:RGS:SCE:DYN:1:IDENT INT01\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:IDENTTYPE}SP <numeric>CR
Description:
This command sets the selected intruder identification type for the Ident
squitter.
Numeric:
1 to 4 (decimal ASCII)
Default:
1
Example:
:RGS:SCE:DYN:1:IDENTTYPE 1\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:DYN: | :DYNAMIC:}<intruder
number>{:SIDENT}{:INT: | :INTERVAL:}<interval number>{:ENA |
:ENABLE}SP{ON | OFF}CR
Description:
This command enables or disables the identification squitter me ssage of the
specified intruder.
Default:
On
Example:
:RGS:SCE:DYN:1:SIDENT:INT:1:ENA ON\r