Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 15
5.5.4
PHASE REQUEST
5.5.5
PORT
Command Syntax:
{:RGS | :RGS2000NG}{:MEA | :MEASURE}{:PHASE?} CR
Description:
This command returns the phase o f the selected pulse between Port 1 and
the selected port.
Return:
Value is in ASCII data format specified in degrees.
In case of the Float data format, the value is returned with one decimal
point.
Example:
:RGS:MEA:PHASE?\r
Returns:
45.1
Command Syntax:
{:RGS | :RGS2000NG}{:MEA | :MEASURE}{:SET | :SETTINGS}{:POR |
:PORT}SP<numeric>CR
Description:
This command sets the receiver port to sample.
Numeric:
0 to 5 (decimal ASCII)
Value
Channel
0
T1/B1
1
T2/B2
2
T3/B3
3
T4/B4
4
Chamber
5
Combiner
Default:
0
Example:
:RGS:MEA:SET:POR 0\r