Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 28
Subject to Export Control. See Cover Page for details.
September 2021
5.8
RTCA/DO-260 TEST COMMANDS
These commands allow the definition of different RTCA/DO-260 tests. The Unit has implemented the
following type of tests: Normal Test, Bit Failures Special Test, Altered Preamble Special Test,
Overlapping Pulse Special Test, Confidence Test and Preamble Validation Test.
The Normal Test is a test that allows the definition of one type of message (Mode S or Mode A/Mode C
or none) for each generator available for the test. The generator available for the test depends on the
power mode (Low Power or High Po wer). In Low Power Mode, all generators are available. In High
Power Mode, only generators GENA, GENC and GENE are available.
For the special tests (Bit Failures, Altered Preamble, Overlapping Pulse, Confidence Test and Preamble
Validation) only two generators are available (GENA and GENC). The generator GENA is used to define
the reference (Mode S message) and generator GENC is used to define the special test.
5.8.1
GENERATOR PARAMETERS
5.8.1.1
Antenna
5.8.1.2
ATCRBS Data
Command Syntax:
Normal Test:
{:RGS | :RGS2000NG}{:DO260}{:TYPE}{:NORMAL }{:GENS}{:GENA | :GENB
| :GENC | :GEND | :GENE | :GENF}{:PATH | :PA}SP{TOP | BOTTOM}CR
Special Test:
{:RGS | :RGS2000NG}{:DO260}{:TYPE}{ :OVERLAPPINGPULSE |
:OVERLAP | :ALTEREDPREAMBLE | :ALT | :BITFAILURES | :BITF |
:PREAMBLEVAL | :PREA}{:GENS}{:GENA | :GENC }{:PATH | :PA}SP{TOP |
BOTTOM}CR
Description:
This command sets the selected generator path to either top or bottom
antenna.
Default:
Top
Example (Normal Test):
:RGS:DO260:TYPE:NORMAL:GENS:GENB:PA BOTTOM\r
Example (Special Test):
:RGS:DO260:TYPE:BITFAILURES:GENS:GENA:PA BOTTOM\r
Command Syntax:
{:RGS | :RGS2000NG}{:DO260}{:TYPE}{:NORMAL} {:GENS}{:GENA | :GENB
| :GENC | :GEND | :GENE | :GENF} {:MODEC} {:DATA}SP<numeric>CR
Description:
This command defines the Mode A /Mode C Code to transmit using the
selected generator.
Numeric:
0 to 7777 (octal ASCII)
Default:
0000 ( Mode A Code)
Example:
:RGS:DO260:TYPE:NORMAL:GENS:GENA:MODEC:DATA 1234\r
NOTE: