Wiring the system
10
Wiring an internal sounder
87
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
10.7
Wiring an internal sounder
To wire an internal sounder to the SPC controller connect the IN+ and IN–
terminals directly to the 12 V sounder input.
Internal sounder wiring (12 V)
IN– IN– (SPC controller)
IN+ IN+ (SPC controller)
10.8
Wiring Glassbreak
SPC supports the RI S 10 D-RS-LED glassbreak interface in combination with
GB2001 glassbreak detectors.
The following diagram shows how the glassbreak interface is wired to the SPC
controller for power, or to an 8-in/2-out expander:
For information on wiring the glassbreak interface to a zone, see the product-
specific documentation.
For information on wiring the glassbreak sensors to the glassbreak interface, see
the product-specific documentation.
10.9
Installing plug-in modules
2 modems (PSTN or GSM) may be installed on the controller board to increase
functionality. The picture below shows the 2 slots available for each modem, the
primary (left) slot and the back-up (right) slot.
If both modem slots are available, always install the plug-in module in the primary
slot; the system always attempts to make PSTN or GSM calls on a modem
installed on the primary slot before attempting to use the back-up slot.
1
2
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...