17
Engineer programming via the browser
Configuration
246
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
edge of the activation signal.
Action
This is the action that is performed when the trigger is
activated. Options are:
Unset
Partset A
Partset B
Fullset
Delay autoset
This action will delay alarm setting when the autoset
timer is running. The trigger will only add time if the Delay
Limit has not been exceeded and each trigger activation
will delay setting by the time defined in Delay Interval
(see section Setting/Unsetting [➙ 243].
Restore alarms
This action will clear all alarms in the configured zone.
Note: Triggers cannot be configured from a keypad.
See also
17.9.5.3
Editing a door
1. Select Configuration > Doors.
A list of configured doors is displayed.
2. Click the Edit button.
3. Configure the fields as described in the tables below.
Door inputs
Each door has 2 inputs with predefined functionality. These two inputs, the door
position sensor and the door release switch can be configured.
Name
Description
Zone
The door position sensor input can be used for the
intrusion part as well. If the door position sensor input is
used also for the intrusion part, the zone number it is
assigned to has to be selected. If the door position
sensor is used only for the access part, the option
“UNASSIGNED” has to be selected.
If the door position sensor is assigned to an intrusion
zone, it can be configured like a normal zone but only
with limited functionality (e.g. not all zone types are
selectable).
If an area or the system is set with the card reader, the
door position sensor input has to be assigned to a zone
number and to the area or the system which have to be
set.
Description
(Web and SPC Pro only)
Description of the zone the door position sensor is
assigned to.
Zone Type
(Web and SPC Pro only)
Zone type of the zone the door position sensor is
assigned to (not all zones types are available).
Zone attributes
(Web and SPC Pro only)
The attributes for the zone the door position sensor is
assigned to can be modified.
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...