3
Directives and standards
EU directives
24
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
An EXIT TERMINATOR zone type must be configured for SPC.
Refer to the following section in this manual:
Zone types [➙ 347]
b) Push button switch mounted outside the supervised premises
Connect the push button into an SPC zone input as follows:
An EXIT TERMINATOR zone type must be configured for SPC.
Refer to the following section in this manual:
Zone types [➙ 347]
c) Protective switch (i.e. door contact) fitted to the final exit door of the alarmed
premises or area
Connect the switch to the SPC System as follows:
The contact is fitted to the final exit door and is connected to an ENTRY/EXIT zone
with a ‘Final Exit‘ attribute.
Refer to the following section in this manual:
Zone types [➙ 347]
Zone attributes [➙ 350]
A misoperation signal is possible using the alarm abort feature. This is enabled by
default.
Refer to the following section in this manual:
OPTIONS [➙ 111] (Kypad)
Options [➙ 222] (Browser)
d) Digital key
Not supported by SPC.
e) In conjunction with an ARC
This method of setting is supported by using SPC COM XT or other third party
ARC software using EDP commands.
Methods of completion of unsetting (BS 8243:2010 - Clause 6.4)
Unsetting methods are complied with as follows:
4K7
Lock - NC, open when locked
Zone – EXIT TERMINATOR zone type
4K7
Tamper
3.1.5.3.2
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...