Intruder alarm functionality
19
Domestic mode operation
321
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
19.3
Domestic mode operation
Domestic mode is suitable for residential installations with one or more areas and a
small-to-moderate number of alarm zones. Each area defined on the system
supports the alarm modes listed below.
Alarm Mode
Description
UNSET
Area is disarmed, only alarm zones classified as 24Hour will activate the alarm.
PARTSET A
This mode provides perimeter protection to a building while allowing free
movement through the exit and access areas (for example front door and hall)
Zones which have been classified as EXCLUDE A remain unprotected in this
mode. There are no Exit times associated with this mode and protection is applied
instantly on selection of this mode.
PARTSET B
This setting mode applies protection to all zones except those that have been
classified as EXCLUDE B.
By default there is no exit time (the system setting instantly on selection of this
mode). An exit timer can be applied to this mode by enabling the Partset B Timed
variable.
FULL SET
Area is fully armed, opening of Entry/Exit zone start the Entry timer. If the alarm is
not unset before the Entry timer expires then the alarm is activated.
19.4
Full and local alarms
The type of alarms generated by the SPC system can vary depending on the type
of zone that triggered the alarm activation. The vast majority of alarms require a
visual (strobe) and audible (bell) indication of an intrusion to the premises or
building.
By default, the first 3 physical outputs on the SPC controller are assigned to the
external bell, internal bell, and external bell strobe. When activated, these 3
outputs together provide sufficient warning of an alarm condition to persons located
inside or within the immediate environment of the building or premises where the
intrusion has taken place.
Full and local alarms on the SPC activate the following physical outputs:
Controller Output 1: External Bell
Controller Output 2: Internal Bell
Controller Output 3: Strobe
For details on how to wire the bells and strobe see page [➙ 72].
A Full Alarm activation reports the alarm to the Alarm Receiving Centre (ARC) if
one has been configured on the system.
A Local Alarm activation does not attempt to call the ARC even if one has already
been configured.
A Silent Alarm activation does not activate outputs 1 – 3 (no visual or audible
indications of the alarm). The alarm event is reported to the ARC. Silent alarms are
only generated when alarm zones with the Silent attribute have been opened when
the system is set.
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...