23
Appendix
CID Codes
342
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
DESCRIPTION
CODE
DEEP CHARGE
XK
LOCKED OUT
WW
23.8
CID Codes
CODE
CID EVENT
DESCRIPTION
100
MEDICAL
Medical and man down alarm and restore.
110
FIRE
120
PANIC
121
DURESS
129
CONFIRMED HOLDUP
See Configuration requirements for PD
130
BURGLARY
134
ENTRYEXIT
137
TAMPER
Cabinet and auxiliary tamper fail and restore.
139
VERIFIED
Confirmed alarm.
144
SENSOR TAMPER
Zone tamper fail and restore.
150
NON BURGLARY
300
SYSTEM TROUBLE
PSU fault and restore.
301
AC LOSS
PSU mains fail and restore.
302
BATTERY LOW
305
RESET
System reset.
311
BATTERY FAIL
PSU battery fail and restore.
312
PSU OVERCURRENT
PSU internal, external and auxiliary fuse fail
and restore.
320
SOUNDER
Bell tamper fail and restore.
330
SYSTEM PERIPHERAL
TROUBLE
PSU fault and restore.
333
EXP FAIL
X-Bus cable and node communications fault
and restore.
338
EXP BATT
X-Bus node battery fault and restore.
341
EXP TAMPER
X-Bus tamper and RF antenna tamper alarm
and restore.
342
EXP AC
X-Bus node mains fault and restore.
344
RF JAM
RF jam fault and restore.
351
TELCO 1
Primary modem fault and restore.
352
TELCO 2
Secondary modem fault and restore.
376
HOLDUP TROUBLE
380
SENSOR TROUBLE
401
OPENCLOSE
Unset, post alarm and fullset.
406
ALARM ABORT
Cancel alarm.
451
EARLY OPENCLOSE
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...