Engineer programming via the keypad
16
X-BUS
121
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
PSU
The type and status of the PSU. (PSU expanders only) Scroll to display the voltage
and current load on the outputs, the battery status. The Mode Link option is also
available, which shows the jumper setting on the panel for the Ah setting. 7Ah and
17Ah are the available options. (This jumper is not present on the 5350 or 6350
models)
If you are using the SPC 5360 or 6350, this menu displays the battery status, and
the status of the fuses on the outputs.
BATTERY
Battery voltage: battery voltage level (PSU expanders only)
INPUT STATE
State of each zone input associated with an expander as follows:
C: Closed, O: Open, D; Disconnected, S: Short (Expanders with inputs only)
16.6.4.3
Edit Keypads
To edit keypads:
1. Scroll to KEYPADS > EDIT.
2. Press SELECT.
3. Scroll to the device to be edited and press SELECT.
The configuration settings for a standard keypad and comfort keypad are
described in the sections below.
4. Press BACK to exit the menu.
LCD Keypad Settings
Configure the following settings for the keypad.
Description
Enter a unique description to identify the keypad.
Function Keys (in idle state)
Panic
Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by
pressing the 2 soft keys together.
Verification
If you assign a verification zone to the keypad, when a panic alarm is triggered
by pressing 2 soft keys together or by entering a duress code, audio and video
events are activated.
Visual Indications
Backlight
Select when keypad backlight is on. Options are: - On after key is pressed;
Always on; Always off..
Indicators
Enable or disable the LED’s on the keypad.
Setting state
Select if setting state should be indicated in idle mode.
Audible Indications
Buzzer
Enable or disable the buzzer on the keypad.
Partset Buzzer
Enable or disable buzzer during exit time on Partset.
Keypress
Select if the speaker volume for the key presses should be activated.
Deactivation
Calendar
Select if the keypad should be limited by calendar. See Calendar [➙ 251].
Mapping gate
Select if keypad should be limited by a mapping gate.
Keyswitch
Select if keypad should be limited by a keyswitch.
PACE Entry
Tick this box to disable the keys on the keypad during the entry time when a
PACE is configured on the keypad.
Areas
Location
Select the secured area where the keypad is located.
Areas
Select which areas can be controlled through keypad.
Options
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...