17
Engineer programming via the browser
Users
188
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Right
User Profile
Type Default
Description
on the keypad each time the system is being set to
remind the user to attend to that zone.
Isolate
Standard*
Manager
Isolating a zone deactivates that zone until such time
as the zone is de-isolated. All zone types on the
controller can be isolated.
Use of this feature to deactivate faulty or open zones
should be considered carefully; once a zone is isolated,
it is ignored by the system and could be overlooked
when setting the system in the future, compromising
the security of the premises.
User Rights - System
Web Access
Standard*
Manager
User can access panel through web browser.
View Log
Standard
Manager
This menu option displays the most recent event on the
keypad display. The event log [➙ 149] details the time
and date of each logged event.
Users
Manager
User can create and edit other users on the panel but
with only the same or less rights than this user.
SMS
Standard*
Manager
This feature allows users to set up the SMS messaging
service if a modem is installed on the system.
Set Date
Standard
Manager
Use this menu option to program the time and date on
the system [➙ 157].
Ensure the time and date information is accurate; these
fields are presented in the event log when reporting
system events.
Change PIN
Standard
Manager
This menu option allows users to change their user
PINS [➙ 150].
Note: To comply with INCERT approvals, the user’s
PIN code must contain more than 4 digits.
View
Video/Video in
Browser
Standard
Manager
User can view video images via the web browser.
Note: The Web Access right must also be enabled for
this function.
Chime
Standard
Manager
All zones that have the CHIME attribute set generate a
short burst of audible tone on the keypad buzzer when
they are opened (while the system is unset).
This menu option allows for enabling or disabling of the
chime feature on all zones.
Engineer
Manager
This option allows users to grant access to engineer
programming.
For Swiss CAT 1 and CAT 2 regional requirements,
when Engineer Access is granted, all areas must be
unset otherwise the engineer will be denied access.
Upgrade
Manager
User can grant manufacturer access to panel to
perform firmware upgrade.
User Rights - Control
Outputs
Standard
Manager
User can activate/deactivate configured outputs
(mapping gates). See Editing an Ouput [➙ 197].
X-10
Standard
Manager
Access Control
User can activate/deactivate configured X-10 devices.
Note: X-10 is in maintenance. The functionality remains
in the system for backward compatibility.
Door Control
Standard*
Manager
Access Control
User can lock/unlock doors.
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...