19
Intruder alarm functionality
Financial mode operation
320
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
19
Intruder alarm functionality
The SPC system can accommodate 3 distinct modes of intruder alarm operation,
Financial, Commercial or Domestic mode, all of which support multiple areas.
Each area in turn can support 4 different alarm modes. Commercial and Financial
mode present more programmable alarm types than Domestic mode. The default
zone name and type settings for each mode is listed in page [➙ 336].
19.1
Financial mode operation
Financial mode is suitable banking and financial businesses that have special
secure areas such as vaults and ATMs.
Each area defined on the system supports the alarm modes listed below.
Alarm Mode
Description
UNSET
Area is disarmed, only alarm zones classified as 24Hour will activate the alarm.
PARTSET A
This mode provides perimeter protection to a building while allowing free
movement through the exit and access areas.
Zones that have been classified as EXCLUDE A remain unprotected in this mode.
By default there is no exit time (the system instantly sets on selection of this
mode). An exit timer can be applied to this mode by enabling the Partset A Timed
variable.
PARTSET B
This setting mode applies protection to all zones except those that have been
classified as EXCLUDE B.
By default there is no exit time (the system instantly sets on selection of this
mode). An exit timer can be applied to this mode by enabling the Partset B Timed
variable.
FULL SET
Area is fully armed; opening of entry/exit zones starts the entry timer. If the alarm
is not unset before entry timer expires, the alarm is activated.
19.2
Commercial mode operation
Commercial mode is suitable for business installations with multiple areas and a
large number of alarm zones. Each area defined on the system supports the alarm
modes listed below.
Alarm Mode
Description
UNSET
Area is disarmed, only alarm zones classified as 24Hour will activate the alarm.
PARTSET A
This mode provides perimeter protection to a building while allowing free
movement through the exit and access areas.
Zones that have been classified as EXCLUDE A remain unprotected in this mode.
By default there is no exit time (the system instantly sets on selection of this
mode). An exit timer can be applied to this mode by enabling the Partset A Timed
variable.
PARTSET B
This setting mode applies protection to all zones except those that have been
classified as EXCLUDE B.
By default there is no exit time (the system instantly sets on selection of this
mode). An exit timer can be applied to this mode by enabling the Partset B Timed
variable.
FULL SET
Area is fully armed; opening of entry/exit zones starts the entry timer. If the alarm
is not unset before entry timer expires, the alarm is activated.
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...