Configuring system latch and auto set outputs [➙ 202]
17.9.1.3
Configuring system latch and auto set outputs
Under Policy, click on the Edit button for the Output Configuration option in
System Options.
The following screen is displayed:
Select the condition under which the latch output is activated:
Entry Time
Output turns on at the end of Exit time and off at the beginning
of Entry time.
Fire Exit
Output turns on if any fire exit zones are active.
Unset
Output turns on if any user unsets system momentary
Alarm Reset
Output turns on if an alarm is reset momentary.
Resetting Alarm
Output turns on during a setting procedure if glass break/smoke
open and not in alarm.
Engineer Exit
Output turns on when an engineer exits from Engineer mode
momentary.
Keypad Valid PIN
Output turns on when valid user PIN entered on keypad and fire
zone is active
Select the behavior of the output.
On
Output will remain on if auto set is active.
Keypad
Output will follow keypad operation.
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...