Engineer programming via the keypad
Areas
116
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Timer
Description
Default
General Settings
RF Output Time
RF OUTPUT
The time that the RF output will remain active on the system.
(0 – 999 seconds)
0 sec.
Time Sync Limit
TIME SYNC LIMIT
Time limit within which no event will be reported.
(0 – 999 secs) Time synchronization only takes place if
system time and update time are outside this limit.
0 sec.
Link Timeout
LINK TIMEOUT
Timeout for Ethernet link fault (0 = Disabled) ( 0 - 250 )
0 secs
Camera Offline
CAMERA OFFLINE
Time for camera to go offline ( 10 - 9999 )
10 secs
Tech. delay
TECH. DELAY
Number of seconds to delay triggering of tech. zones with
tech. delay attribute. (0 – 9999 seconds)
0 sec.
Frequent
FREQUENT
This attribute only applies to Remote Maintenance. The
number of hours a zone must open within if the zone is
programmed with the Frequent use attribute. (1 – 9999 hours)
336 hours (2
weeks)
Duress silent
Time when duress will remain silent and not restorable from
keypad (0 - 999).
0 Minutes
Holdup/panic silent
Number of minutes that a holdup/panic will remain silent and
cannot be restored from the keypad (0 - 999).
0 Minutes
Default times are dependent upon the Engineer configuration. The default times
denoted may or may not be allowable and is dependent on the configuration by
the engineer
16.4
Areas
1. Scroll to AREAS and press SELECT.
2. Scroll to the desired programming option:
ADD
For Domestic and Commercial Mode, the area type defaults to Standard.
In Financial Mode, select area type STANDARD, ATM, VAULT or
ADVANCED.
Enter the name of the area and the preferred entry/exit time.
EDIT
Edit the following settings:
DESCRIPTION
ENTRY EXIT
–
ENTRY TIMER
–
EXIT TIMER
–
NO EXIT TIMER
–
FOB ENTRY ACTIVE
PARTSET A/B
–
ENABLED/DISABLED
–
TIMED
–
ACCESS TO E/EXIT
–
E/EXIT TO ALARM
–
LOCAL
–
NO BELLS
!
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...