17.9.7
Change own PIN
To change a PIN, see Changing Engineer PIN and web password [➙ 194].
17.9.8
Configuring advanced settings
17.9.8.1
Triggers
A trigger is a system state (e.g. zone closing / time / system event (alarm) etc.) that
can be used as inputs to the Cause & Effects. The triggers can be logically
assigned together using the logical operators and / or to create user outputs. The
system supports up to a maximum of 1024 triggers across all its Cause & Effects
system.
1. Select Configuration > Advanced > Triggers.
The following window will be displayed.
2. Configure the fields as described in the table below.
Trigger
System generated number for new trigger.
Trigger will only become active if one of the 2 optional steps (calendar/time
limitation) is configured
Description
Enter a text description for the trigger
Calendar
Select a calendar, if required. If selected, the trigger will only be in effect during
this calendar period. See page [➙ 251].
Active Time/Timer
Enter the number of seconds that the trigger conditions must be true before the
trigger will activate
Time limited
Select a time period between 00:00 and 24:00 during which the trigger will only
be in effect. The Start time is inclusive, the end time is exclusive.
Note: This parameter delays a trigger transition from ON to OFF only; from
OFF to ON is immediate.
Trigger conditions
The trigger is ON if the following conditions are satisfied (i.e. a logical AND
operation is performed):
Zone – the trigger is ON if the configured zone is in one of the following states -
open, closed, short or disconnected.
Door – the trigger is ON if the any of the following door options are configured;
Entry granted, Entry denied, Exit granted, Exit denied, Door open too long,
Door left open, Door forced open, Door normal, Door Locked, Door unlocked
System - the trigger is on if the system output is in the configured state, which
can be on or off. Possible system outputs are “External Bell”, “Alarm”, etc.
Area - the trigger is ON if the area output is in an ON or OFF state. Possible
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...