Enable Early/Late to report any setting and unsetting which is not according to
schedule.
Setting/Unsetting
The following parameters (with the exception of the Interlock parameter) are only
relevant in the following cases:
A Calendar is selected (see Schedule [➙ 240]), or
Unset Duration is enabled (has a value greater than zero), or
Both of the above conditions are met.
Auto Set Warning
Enter the number of minutes to display a
warning before Auto Setting. ( 0 - 30 )
Note that the panel sets either at the
scheduled time or at the time defined by the
Delay Unset parameter. The first warning is
displayed at the configured time before the
scheduled time. There are further warnings
starting at one minute before setting time.
Auto Set Cancel
Enables the user to cancel Auto Setting by
entering a code in the keypad.
Auto Set Delay
Enables a user to delay Auto Setting by
entering a code in the keypad.
Keyswitch
Enables Auto Setting to be delayed using
Keyswitch Expander.
Delay Interval
Enter the number of minutes by which to
delay Auto Set. (1 - 300 )
Delay Counter
Enter the number of times that Auto Setting
can be delayed. (0 – 99: 0 = unlimited)
Delay Unset
Enter the number of minutes by which to
delay an Unset. (0 = no delay)
Interlock Group
Select an Interlock Group to assign to this
area. Interlocking only allows one area
within the group to be Unset at any time.
Typically used in ATM areas.
Unset Duration
If area is Unset for longer than this it will Set
17.9.5.2.6
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...