Appendix
Applicable attributes to zone types
352
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Open Only
This attribute only applies to the KEYARM zone type. If set then the setting
state of the building will toggle on openings only.
Fullset Enable
This attribute only applies to the KEYARM zone type. If this attribute is set
then zone activation will Fullset the system/area. Apply this attribute if it is
intended that the user should only have the ability to FULLSET the system
from a keyarm zone.
Unset Enable
This attribute only applies to the KEYARM zone type. If set then zone
activation will Unset the system/area. Apply this attribute if it is intended that
the user should only have the ability to UNSET the system from a keyarm
zone.
Tech Zone Report
Allows a zone when opened, regardless of the mode to send an alarm to the
ARC in FF, CID, SIA and SIA extended. When areas are selected, the alarm
will only be sent to the ARC to which the area has been assigned to. This
would be a “UA” Unknown Alarm followed by the zone number and text if SIA
extended is selected. It will also send an SMS to the end user and engineer if
select to do so when the unconfirmed alarm filter is selected.
Tech Zone Display
Allows an opening zone to be displayed on the system keypad. The alert led
should also activate. When areas are selected it will only be displayed on the
keypad which is assigned to the area in which the zone has been selected.
The alert may only be displayed on the keypad when the area is in the unset
mode and not in the Part A, Part B and set mode.
Tech Zone Audible
Allows an activated zone to operate the buzzer. This will operate the same as
the Tech Zone Display in the different setting modes and on systems with
areas.
Tech Zone Delay
Allows the zone to have a programmable delay. The delay is variable from 0
to 9999 seconds and will apply to all Tech Zones. The operation is the same
as the Mains Delay timer, if the zone is closed within the delay time, then no
alarm is sent to the ARC, no SMS is sent to the user and the Technical
Output will not trip.
NOTE: The Technical Output will not trip until the delay timer has expired.
Armed report only
Openings are reported only in armed mode.
Fire pre-alarm
If enabled and a fire alarm occurs, a Fire Pre-alarm timer is started and
internal bells and buzzers are activated. (See Timers [➙ 230].) If the alarm is
not cancelled within the timer duration, a fire alarm is confirmed, internal and
external bells are triggered and an event is sent to ARC.
Fire Recognition
If enabled, a Fire Recognition timer is activated which adds extra time to the
Fire Pre-alarm timer duration until a file alarm is reported for the zone. See
Seismic Test/Automatic Sensor
Test
A Seismic zone type may be tested manually or automatically. This attribute
allows automatic testing to be enabled. Refer to the section on timers [➙ 230]
for details of how to configure the timer that determines how often the panel
tests any seismic zones that have this attribute set. The default value for the
timer is 7 days.
Timed
The ‘Timed’ attribute is used for Key Arm zones to delay the setting of an
area. The delay follows the exit timer for the area to which the key arm is
associated.
Verification
Select the configured verification zone to assign to this zone to trigger
audio/video verification.
Force Set
If enabled, the keyarm device can set the system, automatically inhibiting all
open zones.
23.18
Applicable attributes to zone types
The following table shows which attributes are applicable to each zone type:
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...