Engineer programming via the browser
17
Configuration
201
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
RF Output
This output activates when a Fob or WPA button is pressed.
Modem 1 Line Fault
This output activates when there is a line fault on the primary modem..
Modem 1 Failure
This output activates when the primary modem fails.
Modem 2 Line Fault
This output activates when there is a line fault on the secondary modem.
Modem 2 Failure
This output activates when the secondary modem fails.
Battery Low
This output activates when the battery is low,
Entry Status
This output activates if an ‘All Okay’ entry procedure is implemented and there is no
alarm generated i.e. the ‘All Okay’ button is pressed within the configured time after the
user code is entered.
Warning Status
This output activates if an ‘All Okay’ entry procedure is implemented and a silent alarm
generated i.e. the ‘All Okay’ button is not pressed within the configured time after the
user code is entered.
Ready to Set
This output activates when an area is ready to set.
Setting ACK
(SPC Pro — Setting Complete)
This output signals the setting status. The output toggles for 3 seconds to signal that
the setting has failed. The output remains on for 3 seconds if setting is successful.
Fullset Done
(SPC Pro — Setting Success)
This output activates for 3 seconds to signal that the system has been fullest.
Blockschloss 1
Used for normal Blockschloss devices.
When all zones in an area are closed, and there are no pending faults, the
‘Blockschloss 1‘ output is activated. If the lock on the Blockschloss is closed, a
‘Keyarm‘ input is activated, the relevant area is set and the ‘Setting Ack‘ output is
activated for 3 seconds to signal that the setting was successful. ‘Blockschloss 1‘ is not
deactivated.
If the Blockschloss is unlocked, the Blockschloss device deactivates the Keyarm input
to the unset state (closed) and the area is unset. ‘Blockschloss 1‘ is then deactivated.
Blockschloss 2
Used for Blockschloss device type - Bosch Blockschloss, Sigmalock Plus, E4.03.
When all zones in an area are closed, and there are no pending faults, the
‘Blockschloss 2‘ output is activated. If the lock on the Blockschloss is closed, a
‘Keyarm‘ input is activated, the relevant area is set and the ‘Setting Ack‘ output is
activated for 3 seconds to signal that the setting was successful. ‘Blockschloss 2‘ is
then deactivated.
If the Blockschloss is unlocked, the Keyarm zone is switched to unset (closed) and the
area is unset. ‘Blockschloss 2‘ is activated (if area is ready to set).
Lock Element
Activates if the Lock Element is in the ‘locked‘ position.
Unlock Element
Activates if the Lock Element is in the ‘unlocked‘ position.
Code Tamper
Activates if there is a code tamper in the area. Clears when state is reset.
Trouble
Activates if any zone is in trouble state.
Ethernet Link
Activates if there is a fault on the Ethernet link.
Network Fault
Activates if there is an EDP communications fault.
Glass Reset
Used to switch on the power for the glassbreak interface module and to remove power
in order to reset the device. The output is reset if a user enters their code, the zone is
not in the closed state, and the bells deactivated.
Confirmed holdup
Activates in the following scenarios for PD6662 compliance:
two hold-up zone activations more than two minutes apart
a hold-up zone and a panic zone activation more than two minutes apart
If a hold-up zone and a tamper zone or a panic zone and a tamper zone activation
occurs within the two minute period
Full Engineer
Activates if an engineer is on site and the system is in full engineer mode.
*
This output type can only indicate system wide events (no area specific events).
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...