16
Engineer programming via the keypad
System Status
110
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
16
Engineer programming via the keypad
This section provides [Full] Engineer programming options using the LCD keypad
For each menu option, the keypad must be in Full Engineer programming:
1. Enter a valid Engineer PIN (Default Engineer PIN is 1111. For more details,
see Engineering PINs [➙ 102]).
2. Press SELECT for FULL ENGINEER programming.
3. Using the up/down arrow keys, scroll to the desired programming option.
4. A quick select function is implemented. Press # to select a parameter (e.g. a
zone attribute). The selected parameter is displayed with a * (e.g. *Inhibit).
Upon completion of the programming options, the keypad displays UPDATED
momentarily.
16.1
System Status
The System Status feature displays all faults on the system.
To view these faults:
1. Scroll to SYSTEM STATUS.
2. Press SELECT.
The status of the following items is displayed.
Click on each item to display further details.
OPEN ZONES
Displays all open zones.
ALERTS
Displays current alerts on the system.
SOAK
Displays all zones on soak test.
ISOLATIONS
Displays zones that are isolated.
FAIL TO SET
Displays all areas that have failed to set. Select each area to
display details of why the area failed to set.
BATTERY
Displays remaining battery time, voltage and current of
battery. You must enter the Battery capacity and Max current
values in OPTIONS to view the remaining battery time on the
keypad in the event of mains failure. This is indicated under
the STATUS - BATTERY - BATT TIME menu. This menu also
indicates if there is a battery fault.
AUX
Displays voltage and current of auxiliary power.
NOTICE
Users cannot exit from FULL ENGINEER programming if any fault conditions
exist. The first fault will display on the keypad when you attempt to leave engineer
mode. You can view and isolate all faults within the System Status menu under
Alerts and Open Zones.
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...