EntryCheck

™  923P Indoor/Outdoor Keypad is a surface mount 

digital keyless entry system designed for access control applications.  
The backlit keys  are bright and, easy-to-read. A heavy cast vandal 
resistant housing design with mounting plate allows the 923P  to be 
mounted on a rugged surface or on a standard single-gang electrical 
box.  
  
The 923P has a capacity of 500 users. Users can be assigned to use 4 
to 6 digit  PIN codes and/or access cards. An authenticated access   
can be programmed to activate one or both of the relay outputs. 

The timed “anti-passback” feature prevents using the same credentials  
twice  before a programmed waiting period has elapsed.

Two long lasting solid state LED indicators show the status of the 
system.  The left bi-color indicator lights red to indicate power, then 
green when a relay is activated (access grant, etc.).  The right indicator 
flashes yellow to indicate that the keypad is in programming mode.

An internal sounder can be programmed to beep each time a key is 
pressed or when an output is activated.  An internal jumper sets the 
sounder volume high or low.

The 

SENSE 

input can be configured in one of two ways through 

programming .  When configured for “Door Sense”, the input is wired to 
a normally closed door position switch to detect when the door is 
opened or closed.  Forced entry or door ajar situations can then be 
detected. The “Auto-relock” feature can also be used to turn off the 
Main Relay output immediately when the door is closed after access 
has been granted to prevent “tailgating”.
When the 

SENSE 

input is configured for “Inhibit”, the input can be wired 

to a normally open “service” switch or automatic timer that will disable 
access while the switch is closed.

The 

REQUEST-TO-EXIT 

input can be wired to a normally open 

pushbutton to provide codeless activation of the Main Relay, Auxiliary 
Relay, Output #3 or Output #4 (programmable).

The 

ALARM SHUNT 

signal is available when access is granted.  This 

signal can be programmed to activate any of the relays or solid state 
outputs to shunt alarm contacts on the access door/gate  preventing the  
triggering of an alarm when an authorized access occurs.

The 923P 

EntryCheck

™ is powered from a 12 or 24V AC or DC source. 

The non-volatile EEPROM memory retains entry codes and 
programming when power is removed.  An internal jumper is provided 
to reset the master code.  The Main Relay has a 5 Amp capacity.  The 
Auxiliary Relay has a 2 Amp capacity.  Two solid state outputs, capable 
of sinking 100 mA to common are programmable for alarm shunting, or 
to signal forced entry, door ajar, keypad lockout, and keypad active 
conditions.

P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-923P       Rev H       08-21       Page 1

923P

EntryCheck 

TM

SPECIFICATIONS

Mechanical

Dimensions:   1.750" W x 7.3125" H x 1.375" D

      (1.4375” wall projection)

Electrical

Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max

  Output Ratings

   Main Relay: Form “C” 5 Amps @ 28 Volts max

     Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max

Type:  Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum

Environmental

Temperature: -4°F to 140°F (-20°C to 60°C)
Humidity: 5% to 95% non-condensing

 

4 to 6 digit user codes

 

4 independent outputs

 

4 independent timers

 

2 Form C relay contacts

 

2 solid state open collector outputs

 

Program entry codes to activate one or 
two relays

 

Disable input

 

Door sense input

 

Request-to-exit/enter input

 

Keypad tamper lockout

 

Timed anti-passback

 

Anti-tailgate

 

Two LED status indicators

 

Tactile key feel

 

Audible code entry verification

 

12V or 24V, AC or DC operation

                                                                

 

Keypad programmable

 

500 user codes

 

3 User Modes: 

PIN or Card
Card Only
Card and PIN

Features

Security Door Controls

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email [email protected] 

SECURITY DOOR CONTROLS   ■   WWW.SDCSECURITY.COM

[t] 800.413.8783  ■  805.494.0622  ■  E-mail: [email protected]  ■  801 Avenida Acaso, Camarillo, CA  93012  ■  PO Box 3670, Camarillo, CA  93011

INSTALLATION INSTRUCTIONS

Содержание EntryCheck 923P

Страница 1: ...ignal is available when access is granted This signal can be programmed to activate any of the relays or solid state outputs to shunt alarm contacts on the access door gate preventing the triggering of an alarm when an authorized access occurs The 923P EntryCheck is powered from a 12 or 24V AC or DC source The non volatile EEPROM memory retains entry codes and programming when power is removed An ...

Страница 2: ...ELLOW PROGRAM INDICATOR KEYPAD FRONT PROX Antenna QuickStart Programming Examples You must first enter programming mode to perform any function The yellow indicator will blink slowly showing that the 923P EntryCheck is in programming mode Use the option codes to program each function After the new data entry is complete for each function the green indicator will light briefly if the programming ha...

Страница 3: ...orarily disabling the keypad route two wires from the switch or timer to the keypad Connect the inhibit switch timer s normally open contacts to the keypad s SENSE gray E8 and COM black wires terminal Request to Exit Input wiring shown on fig 4 If a request to exit pushbutton is going to be used route two wires from the keypad box to a normally open pushbutton mounted on the secure side of the doo...

Страница 4: ...Input Inhibit Keypad Lockout Output Disabled Keypad Active Output Disabled Beeper Sounds When Key Pressed Yes Beeper Sounds During Relay 1 No Beeper Sounds During Relay 2 No Beeper Sounds During Output 3 No Beeper Sounds During Output 4 No Keypad Lockout Count 3 Tries Before Lockout Anti Passback Time No Anti Passback Auto Relock On BASIC PROGRAMMING When the 923P EntryCheck is in Programming Mode...

Страница 5: ...ess 97 0 0 0 0 0 0 0 0 0 0 0 0 Note The green indicator will light while the memory is being erased This may take up to 15 seconds SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 Erasing Multiple Users Sequential Press 09 1st User Number of users 1st User Starting user number t...

Страница 6: ... when activated default 2 Light always ON Solid state Output 3 On time Default 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation Default No Selects whether or not the keypad beeps during Anti Tamper switch activation Press 45 Sound Sound 1 for Yes 0 for No Changing the Beeper S...

Страница 7: ... 08 21 Page 7 SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 Rubber Gasket Metal Bracket Keypad 1 Secure metal bracket to box or wall 2 Secure keypad to metal bracket using supplied security screw Note Keypad may not conceal single gang box ...

Страница 8: ...o Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 User Employee First Name Employee Last Name 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 P INST INSTRUCTIONS ACCESS CONTROLS INST 923P Rev H 08 21 Page 8 ...

Отзывы: